Bosch D9112B Installation Manual Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
D9112B | Program Entry Guide | 2.0 Area Wide Parameters EN | 32
Bosch Security Systems | 2/04 | 74-06145-000-D
A# Restricted O/C
This item determines if this area can restrict
Opening
and
Closing
report activity.
A
Restricted
Opening
report refers to the panel sending an
Area
Opening
report ONLY when the area is
disarmed after a non-fire alarm.
A
Restricted
Closing
report refers to the panel sending an
Area
Closing
report ONLY when the area has been
master armed with controlled points that were faulted during the arming sequence. The sequence of reports
generated by a restricted closing are:
Was
Forced
Armed
,
Forced
Point
,
Forced
Close
, then
Closing
Report
.
Default: No
Selection: Yes or No
Yes
Restrict
Opening
and
Closing
reports for this area.
A# Area O/C
must be programmed YES to
generate
Restricted
Opening
and
Closing
reports.
Note:
If a passcode is not required for arming or disarming and this item is YES, the area only sends Restricted
Opening and Closing reports. In this case, restricted reports are sent without User ID.
Opening /Closing Window does not affect this report: Windows do not prevent
Restricted
Opening
and
Closing
reports from being sent. Early or late designations are NOT added to
Opening
/Closing reports when they are sent according to the rules for restricted Opening/Closing
reports.
No
Do not restrict
Opening
and
Closing
reports for this area.
Regardless of programming in Authority Levels
L## Restricted O/C
, reports are not restricted in this
area when this item is programmed NO.
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 95 96

Comments to this Manuals