Bosch D9112B Installation Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
D9112B | Program Entry Guide | 2.0 Area Wide Parameters EN | 34
Bosch Security Systems | 2/04 | 74-06145-000-D
A# Auto Close
The panel can automatically arm the area at the end of the closing window.
Default: No
Selection: Yes or No
Yes The area automatically arms at the end of the close window.
When the area is armed automatically, the area sends a
Closing
report without a user ID if
A#
Area O/C
is programmed YES. If
A# Area O/C
is programmed NO, the area automatically arms,
but no
Area
Closing
report is sent. See also
A# Acct O/C
.
When the panel is armed automatically at the end of the closing window, all faulted points
(including non-bypassable points) are force armed, even if the number of faulted points exceeds the
limit set in
A# Force Arm Max
.
No Do not automatically arm the area at the end of the close window.
A# Fail To Open
This entry allows you to determine if
Fail to Open
reports are sent.
Default: 0
Selection: 0 or 1
Yes
Fail to Open
reports are sent to the central station, logged, and recorded on a local printer (if
installed) at the end of the opening window if the area has not been disarmed. Normal
Opening
and
Closing
reports do not need to be programmed to use this feature.
No
No
Fail to Open
reports or log events are generated.
A# Fail To Close
This entry allows you to determine if
Fail to Close
reports are sent.
Default: 0
Selection: 0 or 1
Yes
Fail to Close
reports are sent to the central station, logged, and recorded on a local printer (if
installed) at the end of the closing window if the area was not armed. An exit delay time must be
programmed in
Exit Dly Time
. Normal
Opening
and
Closing
reports do not need to be
programmed to use this feature.
If
Auto Close
is programmed YES, a
Fail to Close
report is sent. If
Disable O/C in Window
is
YES, the
Fail to Close
report is followed by
Closing
Late
or
F(orce
)
Close
Late
.
No
No
Fail to Close
reports or log events are generated.
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 95 96

Comments to this Manuals

No comments