Master Arm
There are three arming functions enabled by this prompt:
Master Arm All Areas: Arms all areas according to the
Scope
of the command center where the function is
entered (see Cmd Cntr Assignment).
Master Arm an Area: Allows the user to select a single area to arm.
Command 1: Local area arming; only arms the area where the command center is assigned.
How command center Scope affects area execution:
An Area Command Center can execute this function only in the area where the command center is
assigned. An Account Command Center can execute this function in all areas in the account where the
user has authority. A Panel-Wide Command Center can execute this function in all areas in the panel
where the user has authority.
Default: P
Selection: Blank, E, or P
Blank Disable the function panel-wide. Attempting to access the function displays NO AUTHORITY.
E Enable this function panel-wide. The function can be executed from any area within the command
center’s Scope without entering a passcode.
Programming in O/C Options Area O/C and Restricted O/C determines whether
Opening
and
Closing
reports can be generated for a particular area.
P Passcode required. When the passcode is entered at the command center, the panel checks the
authority level.
The panel only arms areas where the passcode is authorized that are within the Scope of the
command center. The command center display shows the areas it is arming.
0101
0101
0101
Force Arming: If a passcode is not required to arm these functions, all authority levels can force arm. To
disable force arming in an area, enter 0 in FA Bypass Max in the Area Parameters section of the program.
L## Master Arm
Default: See
Program Record Sheet
Selection: Blank or E
Blank Disable this function for Authority Level (L##) specified, if this item in Command Center Function
requires a passcode (P).
E Enable this function for Authority Level specified. When the passcode is entered at the command
center, the panel checks the authority level. The panel executes the function only in areas where the
passcode is authorized.
Programming in O/C Options
Area O/C
and
Restricted O/C
determines whether
Opening
and
Closing
reports can be generated for a particular area.
Whether
Opening
and
Closing
reports are generated by this user or not depends on the
L##
Area O/C
and
L## Restricted O/C
prompts in Authority Lvl Assign.