Bosch D9112B Installation Manual Page 56

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 55
D9112B | Program Entry Guide | 3.0 User Interface EN | 56
Bosch Security Systems | 2/04 | 74-06145-000-D
L## Chg Passcode
Default: See
Program Record Sheet
Selection: Blank or E
Change Passcodes:
See Authority Level Selections in the introduction to the
Authority Lvl Assign programming module for
descriptions of selections.
Add Passcode
Default: P
Selection: Blank, E, or P
Add Passcode [COMMAND] [5] [6]:
Add user numbers, associated passcodes, and assign
authority levels for each area. This is a panel-wide
function that can be executed from any command
center assigned to an area where the user has
authority.
Bosch Security Systems recommends this item be
programmed P or disabled.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Add Passcode
Default: See
Program Record Sheet
Selection: Blank or E
Add Passcode: See Authority Level Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
Del Passcode
Default: P
Selection: Blank, E, or P
Delete Passcode:
Delete user numbers and associated passcodes from
the system. This is a panel-wide function that can
be executed from any command center assigned to
an area where the user has authority.
Bosch Security Systems recommends this item be
programmed P or disabled.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Del Passcode
Default: See
Program Record Sheet
Selection: Blank or E
Delete Passcode: See Authority Level Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
Extend Close
Default: P
Selection: Blank, E, or P
Extend Close:
Change the expected closing time for the area where
the function is entered. The window cannot be
adjusted until the
Close Early Begin
time has
passed and the closing window is active.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Extend Close
Default: See
Program Record Sheet
Selection: Blank or E
Extend Close: See Authority Level Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
View Log
Default: E
Selection: Blank, E, or P
View Log: This is a panel-wide function that can
be executed from any command center assigned to
an area where the user has authority.
This command center function allows the user to
view all of the events stored in the D9112 log. This
is particularly useful for system troubleshooting.
Every time an event is generated, the event is sent to
the log. Many events have “modifiers” attached to
them. Modifiers are stored in the log as separate
events. For example, each time an area is force
armed several events are sent to the log.
The log in the D9112 can store up to 499 events
panel-wide. When the number of stored events
exceeds 499, the panel overwrites the oldest event,
regardless of the area in which it occurred. See
Log
% Full
in RAM Parameters for more information
about the event log.
Page view 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 95 96

Comments to this Manuals

No comments