D9112B | Program Entry Guide | 7.0 Point Index EN | 71
Bosch Security Systems | 2/04 | 74-06145-000-D
4
There are two ways to use
Point Type
4 to arm and disarm an area:
Keyswitch Maintain: Program
Point Response
as 1. Do not connect initiating devices to a
Keyswitch point.
Normal: The area is disarmed
Open: When this point changes from normal to open, the area arms.
Short: A short is a trouble while the area is disarmed.
A short is an alarm while the area is armed.
When this point changes from shorted to normal or open, it restores.
Trouble
and
Restoral
reports are not sent if
Local Disarmed
is YES.
Alarm
and
Restoral
reports are not sent if
Local Armed
is YES.
D279: Program
Point Response
as 2. The D279 should be the ONLY point in the area. The scope
of an account command center should be programmed to include the D279’s area.
Cut the W1 jumper on the D279 to send
Area
Opening
and
Closing
reports as programmed in
Area Parameters and to provide bell control. If the D279’s W1 jumper is NOT cut then no
Area
Open
or
Area
Close
report is sent, and alarm bells can only be silenced from a command center,
no matter how the D9112 is programmed.
Normal: When this point changes from open to normal, the area arms.
Open: The area is disarmed. The alarm bell silences if an alarm occurred while the area was
armed.
Short: A short is a trouble while the area is disarmed.
A short is an alarm while the area is armed.
When this point changes from shorted to normal or open, it restores but does not send a
Restoral
report.
5
Keyswitch Momentary: Used for Area Arming and Disarming.
Point Response
must be
programmed 1. Do not connect initiating devices to a Keyswitch point.
NSN: When this point momentarily changes from normal to shorted to normal, it toggles the
armed state of the area.
Open: An open is a trouble while the point is disarmed.
An open is an alarm while the point is armed.
When this point changes from shorted to normal to open, it restores.
Trouble
and
Restoral
reports are not sent if Local Disarmed is YES.
Trouble
and
Restoral
reports are not sent if Local Armed is YES.
6
Open/Close: Used for Point Arming and Disarming.
Point Response
must be programmed 1.
Local bells are silenced through the command center.
Normal: The point is armed and sends
Point Closing. Point Closing
is not sent if
Local Alarm
is
YES.
Open: An open is an alarm while the point is armed.
An open is a trouble while the point is disarmed.
Alarm
and
Restoral
reports are not sent if
Local Disarmed
is YES.
Short: The point is disarmed and sends
Point Opening
. Local bells are silenced if they were
sounding.
Point Opening
is not sent if
Local Armed
is YES.