64 en | Configuration via IP, Advanced Mode Dinion IP Infrared Imager
F.01U.263.416 | 3.1 | 2012.09 User Manual Bosch Security Systems, Inc.
P-frame quality
This setting allows you to adjust the maximum image quality of
the P-frames. The basic setting Auto automatically adjusts to
the optimum combination of movement and image definition
(focus). Alternatively, you can use the slide control to set a
value between 9and51. The value of 9 represents the best
image quality with, if necessary, a lower frame refresh rate
depending on the settings for the maximum data rate. The value
of 51 results in a very high refresh rate and lower image quality.
Default
Click Default to return the profile to the factory default values.
9.3.9 Encoder Streams
Select the property and default profile for each H.264 stream
and set the parameters for the M-JPEG stream.
The choices for Stream 1 depend on the resolution setting in
the Installer Menu page (Section 9.3.11 Installer Menu, page 66).
For the first H.264 stream, you have these options:
To select the stream options:
1. Select the required encoder properties and one of the
encoder profiles for each data stream.
2. Click the Preview button. The preview screens for both
data streams are shown.
3. Click the 1:1 Live View button below the preview screen to
open a new window with the original data stream and to
check the image quality and the transmission rate.
Property
Select one of the H.264 standards for each stream.
H.264 BP+ bit-rate-limited
(1.2 Mbps)
H.264 MP SD
CABAC Off On
CAVLC On Off
GOP structure IP IP
I-frame distance 15 30
Deblocking filter On On
Recommended
for:
Hardware decoders,
Divar XF digital video
recorder
Software decoders,
PTZ, and rapid
image movements
Page view 63