Dinion IP Infrared Imager Configuration via IP, Advanced Mode | en 85
Bosch Security Systems, Inc. User Manual F.01U.263.416 | 3.1 | 2012.09
Attach JPEG from camera
Select this checkbox to specify that JPEG images are sent from
the camera. An enabled video input is indicated by a check
mark.
Destination address
Enter the e-mail address for alarm e-mails here. The maximum
address length is 49 characters.
Sender name
Enter a unique name for the e-mail sender, for example the
location of the unit. This will make it easier to identify the origin
of the e-mail.
Test e-mail
You can test the e-mail function by clicking the Send Now
button. An alarm e-mail is immediately created and sent.
9.5.4 Alarm Task Editor
As an alternative to the alarm settings on the various alarm
pages, you can enter your desired alarm functions in script form
here. This will overwrite all settings and entries on the other
alarm pages.
1. Click the Examples link under the Alarm Task Editor field
to see some script examples. A new window will open.
2. Enter new scripts in the Alarm Task Editor field or change
existing scripts in line with your requirements.
3. When you finish, click the Set button to transmit the
scripts to the unit. If the transfer was successful, the
message Script successfully parsed is displayed over the
text field. If it was not successful, an error message will be
displayed with further information.
CAUTION!
Editing scripts on this page overwrites all settings and entries
on the other alarm pages. This procedure cannot be reversed.
In order to edit this page, you must have programming
knowledge and be familiar with the information in the Alarm
Task Script Language document.