Bosch D9412GV4 Installation Guide Page 158

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 157
158 en | Schedules (Skeds) D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
Figure 6.2 Programming for Two Same Day Opening Windows (refer to Figure 6.1, Page 157)
Do not program a single window to cross the midnight boundary. The window stop time must
be later than the window start time. To program a window that effectively crosses the
midnight boundary, you must program two windows.
For example, to program windows for an area that opens between 11:30 PM and 12:30 AM,
five days a week, use two windows as shown in Figure 6.3.
Figure 6.3 Programming to Link Two Days over Midnight*
W# Close Early Begin
Close Early Begin: This program item is one of three required to create a Closing Window. To
finish programming a Closing Window, Close Window Start and Close Window Stop must be
programmed.
The time programmed in the Close Early Begin field is the earliest time the user can close an
area before the Closing Window Start time. If Opening and Closing Reports are enabled,
arming the area between midnight and the Close Early Begin time generates a Closing Report.
Additionally:
–If A# Disable O/C in Window is set to Yes and the area is armed between the Close Early
Begin time and the Close Window Start time, the Closing Event is sent with an Early to
Close modifier. If the Close Early Begin time is the same as the Close Window Start time,
no Closing Event is sent.
–If A# Disable O/C in Window is set to No and the area is armed at any time, a Closing
Event is sent without the Early to Close or late to Close modifiers.
Arming the area between the Close Window Start and Close Window Stop times creates a
local event in the control panel event log, but does not send the Closing Report to the central
station.
Arming the area after the Close Window Stop time and before the next window’s Close Early
Begin time (or midnight, whichever is earlier) generates a Closing Event with a Late to Close
modifier.
When configuring multiple windows to operate on the same day, ensure that they are added
to the system in chronological order. For example, if three windows are programmed to
execute on Tuesday, Window 1 (W1) must occur before Window 2 (W2), and Window 2 must
occur before Window 3 (W3).
Default: 00:00
Selection: HH:MM (hours and minutes)
00:00 to 23:59
Page view 157