60 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
This program item determines when a passcode entry with L# Send Duress authority should
produce a duress alarm.
For SIA CP-01 Compliance Duress Type must be set to 3.
Cancel Report
A Cancel and Fire Cancel Report is created when a passcode is entered to silence an Alarm
Bell or a Fire Bell before the bell time expires.
For SIA CP-01 Compliance Duress Type this prompt must be set to Yes.
Call for Service Text
On-site Authorization for Firmware Update
Perform firmware updates using RPS. RPS Online Help includes instructions for using the
Firmware update feature.
2 Increase the last digit by 2 to generate an alarm. For example, if the
passcode is 6123, 6125 activates a duress alarm.
If the last digit of the passcode is 8, a duress alarm occurs when the
user enters 0 as the last digit of the passcode.
If the last digit of the passcode is 9, a duress alarm occurs when the
user enters 1 as the last digit of the passcode.
3 Send a Duress event when any Passcode with L# Send Duress set to
Yes is entered.
NOTICE!
Duress is enabled in Area Parameters by setting A# Duress Enable to Yes.
NOTICE!
The duress alarm activates when a user enters the duress passcode followed by the
termination keys ([ESC] or [ENT]).
Default: Yes
Selection: Yes or No
Yes Send Cancel and Fire Cancel Reports according to routing.
No Do not send Cancel and Fire Cancel Reports.
Default: "Contact your dealer"
Selection: Twenty alphanumeric characters
Enter the text to display on a D1260 series keypad when the control panel is out of service.
Default: No
Selection: Yes or No
Yes Authorized personnel on-site must enter the authorization code at one
of the command centers at the designated time during the remote
firmware update process.
No No on-site authorization is required.
NOTICE!
It is recommend that a full system test be performed whenever firmware is updated locally or
remotely.