D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 91
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
Figure 3.4 Softkey Locations on the D1260 Keypad
Programming Custom Function Keystrokes
– Find the command you want to execute in the User Interface section of the program
record sheet. Single digit commands must be programmed with 9 as the second digit.
Table 3.16 CF### Custom Function Keystrokes
– When CF### Custom Function is programmed with P, the corresponding custom
function number is passcode protected. The CF### Custom Function prompt is under
User Interface > Cmd Center Functions. The passcode protected custom function can be
added to a keypad’s function list by programming its number in the Function List > M#
Function prompt.
– 128 to 143 Enable Custom Function 128 through 143 (128 through 131 for D7412GV4/
D7212GV4) (Menu Function only): This function determines if a passcode is needed to
Callout Description
1 Softkey 1 (C1)
2 Softkey 2 (C2)
3 Softkey 3 (C3)
4 Softkey 4 (C4)
5 Softkey 5 (C5)
6 Softkey 6 (C6)
7 Softkey 7 (C7)
8 Softkey 8 (C8)
Command Keystrokes
1 (Master arm area) A19
2 (Perimeter instant arm) A29
3 (Perimeter delay arm) A39
6 (Watch mode) A69
7 (Special alert) A79
8 (Perimeter partial arm) A89
9 (Special alert) A99
0 (Bypass a point) A09
Comments to this Manuals