10 SIA CP-01 Quick Reference
Table 10.1 Programming the Control Panels for SIA CP-01 Compliance
Product Name Bosch Recommended Settings for
SIA CP-01 Compliance
Shipping Default Reference
Page
Phone # (Prefix backup phone number with
Call Waiting disable command)
{Blank} 17
Duress Type Option 3 0 (disabled) 59
Cancel Report Yes Yes 60
A# Exit Dly Time 45 sec to 255 sec 60 sec 63
A# Duress Enable Yes No 64
A# Exit Restart Yes or No Yes 77
A# Arm No Exit Yes or No Yes 78
A# Two Man Rule No No 74
A# Early Ambush No No 76
A# Exit Warning Yes Yes 78
A# Burg Time 6 min to 90 min 6 min 67
A# Alarm Bell 1 to 128 (64), A, B, C A (on-board alarm
output)
118
A# Verify Time 10 sec to 60 sec 60 sec 63
CC# Entry Tone Yes or No Yes 86
CC# Exit Tone Yes or No Yes 86
CC# Abort Display Yes or No Yes 87
CC# Cancel Display Yes or No Yes 88
CC# Pass Code
Enter Function
Arm/Disarm Arm/Disarm 83
CC# Dual
Authentication
No No 84
Master Arm Instant - - 94
Perimeter Instant - - 94
L## Send Duress - or E
E
2
113
L## Disarm - or E
E
2
103
L## Passcode
Disarm
- or E
E
2
113
P## Entry Delay 30 sec to 240 sec 30 sec 134
P## Alarm Abort Yes or No
Yes
3
145
Abort Window 15 sec to 45 sec 30 sec 176
Passcode Length 3 to 6 digits Disabled 177
Swinger Count 1 to 2 trips 1 trip 177
Remote Warning Yes Yes 177
Cross Point Time 5 to 255 sec 20 sec 143
P## Cross Point Yes or No No 143
1
The SIA allowed range is 1 min to 90 min. Must additionally comply with UL requirements, refer to
Section A# Burg Time, page 67.
2
L14 is the default duress user index.
3
The default for P## Alarm Abort is No for P3, P4, P5, and P22.